Chromalox 2104 manual
Chromalox Technical Manual Page Controller is capable of single output and Control heat/cool PID control. The selection for single or Operation heat/cool control is made in the Controller Type menu (CTRL PAGE, CONT) with PID settings also in the Control Page. The Chromalox® 1/4 DIN temperature controller is a high-performance, single-loop controller. The controller has two control outputs for heating and cooling that can be configured separately and provide flexible temperature control. A dual digital display of . The Chromalox 1/4 DIN Temperature and Process Controller is a low cost, high performance single loop controller that can be used for temperature, flow, pressure and level control applications. With universal sensor inputs and front panel operator setup, one controller can be easily field configured.
A Controls Indicators from CHROMALOX In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, TEMPERATURE CONTROLLER, SERIES, 1/4 DIN, ANALOG MA / V DC, V AC SUPPLY, 50/60 HZ. Wiring Chromalox Technical Manual The CLP is not a substitute for safety shutdown devices such as flow switches or overtemperature monitors. Chromalox rr RR Temperature Controller Page 53 Inhibit is adjustable for each alarm output. Chromalox Technical Manual A Digital Input that is hardwired to terminals 1 and 2 of the controller. Page 4 3-Wire mA, Vdc Transmitter When driving a contactor coil or other inductive load, an appropriately rated AC snubber circuit is recommended Chromalox Part.
Read and understand all instructions in this user’s manual and the enclosed temperature control instruction manual before attempting to install or operate system. Congratulations on purchasing the Chromalox CMX Series mi-croTHERM™ Temperature Control System. This system has been thoroughly engineered, carefully built, and fully tested to. Chromalox ® Chromalox ® Chromalox ® QuickInfo Outputs #1 and #2 M E N U De scription A vailable Settings C Y C1 C1 Output #1 Cycle to seconds Time = Voltage/Current algorithm OL OL 1 1 Output #1 Limit to % H H OFF Heat Offset 0 ° F to PB1 setting Outputs #3, #4 and #5 M E N U De scription A vailable Settings T Y P3 P3 Output #3 Type OFF = Disabled A LR = Alarm Output E NT. Chromalox Technical Manual 7 Figure Wiring Terminal Identification Sensor Input Wiring Sensor Input Wiring Notes: •Sensor leads (thermocouple and RTD) should not be run together in the same conduit as power wiring. •Twisted pair, shielded wire is recommended for sensor connections. •False process readings can occur if the sensor wire.
0コメント